A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers

Magnetoencephalography (MEG) measures brain function via assessment of magnetic fields generated by neural currents. Conventional MEG uses superconducting sensors, which place significant limitations on performance, practicality, and deployment; however, the field has been revolutionised in recent years by the introduction of optically-pumped-magnetometers (OPMs). OPMs enable measurement of the MEG signal without cryogenics, and consequently the conception of OPM-MEG systems which ostensibly allow increased sensitivity and resolution, lifespan compliance, free subject movement, and lower cost. However, OPM-MEG remains in its infancy with limitations on both sensor and system design. Here, we report a new OPM-MEG design with miniaturised and integrated electronic control, a high level of portability, and improved sensor dynamic range (arguably the biggest limitation of existing instrumentation). We show that this system produces equivalent measures when compared to an established instrument; specifically, when measuring task-induced beta-band, gamma-band and evoked neuro-electrical responses, source localisations from the two systems were highly comparable and temporal correlation was >0.7 at the individual level and >0.9 for groups. Using an electromagnetic phantom, we demonstrate improved dynamic range by running the system in background fields up to 8 nT. We show that the system is effective in gathering data during free movement (including a sitting-to-standing paradigm) and that it is compatible with simultaneous electroencephalography (EEG - the clinical standard). Finally, we demonstrate portability by moving the system between two laboratories. Overall, our new system is shown to be a significant step forward for OPM-MEG technology and offers an attractive platform for next generation functional medical imaging.

neuroscience↗

Test-Retest Reliability of the Human Connectome: An OPM-MEG study

Magnetoencephalography with optically pumped magnetometers (OPM-MEG) offers a new way to record electrophysiological brain function, with significant advantages over conventional MEG including adaptability to head shape/size, free movement during scanning, better spatial resolution, increased signal, and no reliance on cryogenics. However, OPM-MEG remains in its infancy, with significant questions to be answered regarding optimal system design and robustness. Here, we present an open-source dataset acquired using a newly constructed OPM-MEG system with a triaxial sensor design averaging 168 channels. Using OPM-optimised magnetic shielding and active background-field control, we measure the test-retest reliability of the human connectome. We employ amplitude envelope correlation to measure whole-brain functional connectivity in 10 individuals whilst they watch a 600 s move clip. Our results show high repeatability between experimental runs at the group level, with a correlation coefficient of 0.81 in the theta, 0.93 in alpha and 0.94 in beta frequency ranges. At the individual subject level, we found marked differences between individuals, but high within-subject robustness (correlations of 0.56 {+/-} 0.25, 0.72 {+/-} 0.15 and 0.78 {+/-} 0.13 in theta, alpha and beta respectively). These results compare well to previously reported findings using conventional MEG; they show that OPM-MEG is a viable way to characterise whole brain connectivity and add significant weight to a growing argument that OPMs can overtake cryogenic sensors as the fundamental building block of MEG systems.

neuroscience↗

Using OPM-MEG in contrasting magnetic environments

Magnetoencephalography (MEG) has been revolutionised in recent years by optically pumped magnetometers (OPMs). "OPM-MEG" offers higher sensitivity, better spatial resolution and lower cost than conventional instrumentation based on superconducting quantum interference devices (SQUIDS). Moreover, OPMs offer the possibility of motion robustness and lifespan compliance, dramatically expanding the range of MEG applications. However, OPM-MEG remains nascent technology; it places stringent requirements on magnetic shielding, and whilst a number of viable systems exist, most are custom made and there have been no cross-site investigations showing the reliability of data. In this paper, we undertake the first cross-site OPM-MEG comparison, using near identical commercial systems scanning the same participant. The two sites are deliberately contrasting, with different magnetic environments: a "green field" campus university site with an OPM-optimised shielded room (low interference) and a city centre hospital site with a "standard" (non-optimised) MSR (high interference). We show that despite a 25-fold difference in background field, and a 30-fold difference in low frequency interference, using dynamic field control and software-based suppression of interference we can generate comparable noise floors at both sites. In human data recorded during a visuo-motor task and a face processing paradigm, we were able to generate similar data, with source localisation showing that brain regions could be pinpointed with just ~10 mm spatial discrepancy and temporal correlations of > 80%. Overall, our study demonstrates that "plug- and-play" OPM-MEG systems exist and can be sited even in challenging magnetic environments.

neuroscience↗

Phenotypic and genetic associations of quantitative magnetic susceptibility in UK Biobank brain imaging

A key aim in epidemiological neuroscience is identification of markers to assess brain health and monitor therapeutic interventions. Quantitative susceptibility mapping (QSM) is an emerging MRI technique that measures tissue magnetic susceptibility and has been shown to detect pathological changes in tissue iron, myelin and calcification. We developed a QSM processing pipeline to estimate magnetic susceptibility of multiple brain structures in 35,885 subjects from the UK Biobank prospective epidemiological study. We identified phenotypic associations of magnetic susceptibility that include body iron, disease, diet, and alcohol consumption. Genome-wide associations related magnetic susceptibility to genetic variants with biological functions involving iron, calcium, myelin, and extracellular matrix. These patterns of associations include relationships that are unique to QSM, in particular being complementary to T2* measures. These new imaging phenotypes are being integrated into the core UK Biobank measures provided to researchers world-wide, creating potential to discover novel, non-invasive markers of brain health.

neuroscience↗

Magnetic Field Mapping and Correction for Moving OP-MEG

BackgroundOptically pumped magnetometers (OPMs) have made moving, wearable magnetoencephalography (MEG) possible. The OPMs typically used for MEG require a low background magnetic field to operate, which is achieved using both passive and active magnetic shielding. However, the background magnetic field is never truly zero Tesla, and so the field at each of the OPMs changes as the participant moves. This leads to position and orientation dependent changes in the measurements, which manifest as low frequency artefacts in MEG data. ObjectiveWe modelled the spatial variation in the magnetic field and used the model to predict the movement artefact found in a dataset. MethodsWe demonstrate a method for modelling this field with a triaxial magnetometer, then showed that we can use the same technique to predict the movement artefact in a real OPM-based MEG (OP-MEG) dataset. ResultsUsing an 86-channel OP-MEG system, we found that this modelling method maximally reduced the power spectral density of the data by 26.2 {+/-} 0.6 dB at 0 Hz, when applied over 5 s non-overlapping windows. ConclusionThe magnetic field inside our state-of-the art magnetically shielded room can be well described by low-order spherical harmonic functions. We achieved a large reduction in movement noise when we applied this model to OP-MEG data. SignificanceReal-time implementation of this method could reduce passive shielding requirements for OP-MEG recording and allow the measurement of low-frequency brain activity during natural participant movement.

neuroscience↗

Measuring functional connectivity with wearable MEG

Optically-pumped magnetometers (OPMs) offer the potential for a step change in magnetoencephalography (MEG) enabling wearable systems that: provide improved data quality; accommodate any subject group; allow data capture during movement and offer a reduction in costs. However, OPM-MEG is still a nascent technology and, to realise its potential, it must be shown to facilitate key neuroscientific measurements, such as the characterisation of human brain networks. Networks, and the connectivities that underlie them, have become a core area of neuroscientific investigation, and their importance is underscored by many demonstrations of their perturbation in brain disorders. Consequently, a demonstration of network measurements via OPM-MEG would be a significant step forward. Here, we aimed to show that a wearable 50-channel OPM-MEG system enables characterisation of the electrophysiological connectome. To this end, we characterise connectivity in the resting state and during a simple visuo-motor task, using both OPM-MEG and a state-of-the-art 275-channel cryogenic MEG device. Our results show that connectome matrices from OPM and cryogenic systems exhibit an extremely high degree of similarity, with correlation values >70 %. This value is not measurably different to the correlation observed between connectomes measured in different subject groups, on a single scanner. In addition, similar differences in connectivity between individuals (scanned multiple times) were observed in cryogenic and OPM-MEG data, again demonstrating the fidelity of OPM-MEG data. This demonstration shows that a nascent OPM-MEG system offers results similar to a cryogenic device, even despite having [~]5 times fewer sensors. This adds weight to the argument that OPMs will ultimately supersede cryogenic sensors for MEG measurement.

neuroscience↗

Multi-centre, multi-vendor reproducibility of 7T QSM and R2* in the human brain: results from the UK7T study

We present the reliability of ultra-high field T2* MRI at 7T, as part of the UK7T Networks "Travelling Heads" study. T2*-weighted MRI images can be processed to produce quantitative susceptibility maps (QSM) and R2* maps. These reflect iron and myelin concentrations, which are altered in many pathophysiological processes. The relaxation parameters of human brain tissue are such that R2* mapping and QSM show particularly strong gains in contrast-to-noise ratio at ultra-high field (7T) vs clinical field strengths (1.5 - 3T). We aimed to determine the inter-subject and inter-site reproducibility of QSM and R2* mapping at 7T, in readiness for future multi-site clinical studies. MethodsTen healthy volunteers were scanned with harmonised single- and multi-echo T2*-weighted gradient echo pulse sequences. Participants were scanned five times at each "home" site and once at each of four other sites. The five sites had 1x Philips, 2x Siemens Magnetom, and 2x Siemens Terra scanners. QSM and R2* maps were computed with the Multi-Scale Dipole Inversion (MSDI) algorithm (https://github.com/fil-physics/Publication-Code). Results were assessed in relevant subcortical and cortical regions of interest (ROIs) defined manually or by the MNI152 standard space. Results and DiscussionMean susceptibility ({chi}) and R2* values agreed broadly with literature values in all ROIs. The inter-site within-subject standard deviation was 0.001 - 0.005 ppm ({chi}) and 0.0005 - 0.001 ms-1 (R2*). For {chi} this is 2.1-4.8 fold better than 3T reports, and 1.1-3.4 fold better for R2*. The median ICC from within- and cross-site R2* data was 0.98 and 0.91, respectively. Multi-echo QSM had greater variability vs single-echo QSM especially in areas with large B0 inhomogeneity such as the inferior frontal cortex. Across sites, R2* values were more consistent than QSM in subcortical structures due to differences in B0-shimming. On a between-subject level, our measured {chi} and R2* cross-site variance is comparable to within-site variance in the literature, suggesting that it is reasonable to pool data across sites using our harmonised protocol. ConclusionThe harmonized UK7T protocol and pipeline delivers on average a 3-fold improvement in the coefficient of reproducibility for QSM and R2* at 7T compared to previous reports of multi-site reproducibility at 3T. These protocols are ready for use in multi-site clinical studies at 7T.

neuroscience↗

Mouth magnetoencephalography: A unique perspective on the human hippocampus

Traditional magnetoencephalographic (MEG) brain imaging scanners consist of a rigid sensor array surrounding the head; this means that they are maximally sensitive to superficial brain structures. New technology based on optical pumping means that we can now consider more flexible and creative sensor placement. Here we explored the magnetic fields generated by a model of the human hippocampus not only across scalp but also at the roof of the mouth. We found that simulated hippocampal sources gave rise to dipolar field patterns with one scalp surface field extremum at the temporal lobe and a corresponding maximum or minimum at the roof of the mouth. We then constructed a fitted dental mould to accommodate an Optically Pumped Magnetometer (OPM). We collected data using a previously validated hippocampal-dependent task to test the empirical utility of a mouth-based sensor, with an accompanying array of left and right temporal lobe OPMs. We found that the mouth sensor showed the greatest task-related theta power change. We also found that, as predicted by the simulations, the mouth sensor was anti-correlated with those on over the temporal lobes. We found that this sensor had a mild effect on the reconstructed power in the hippocampus (~10% change) but that coherence images between the mouth sensor and reconstructed source images showed a global maximum in the right hippocampus. We conclude that augmenting a scalp-based MEG array with sensors in the mouth shows unique promise for both basic scientists and clinicians interested in interrogating the hippocampus.

neuroscience↗

Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System

Magnetoencephalography (MEG) is a powerful technique for functional neuroimaging, offering a non-invasive window on brain electrophysiology. MEG systems have traditionally been based on cryogenic sensors which detect the small extracranial magnetic fields generated by synchronised current in neuronal assemblies, however such systems have fundamental limitations. In recent years quantum-enabled devices, called optically-pumped magnetometers (OPMs), have promised to lift those restrictions, offering an adaptable, motion-robust MEG device, with improved data quality, at reduced cost. However, OPM-MEG remains a nascent technology, and whilst viable systems exist, most employ small numbers of sensors sited above targeted brain regions. Here, building on previous work, we construct a wearable OPM-MEG system with whole-head coverage based upon commercially available OPMs, and test its capabilities to measure alpha, beta and gamma oscillations. We design two methods for OPM mounting; a flexible (EEG-like) cap and rigid (additively-manufactured) helmet. Whilst both designs allow for high quality data to be collected, we argue that the rigid helmet offers a more robust option with significant advantages for reconstruction of field data into 3D images of changes in neuronal current. Using repeat measurements in two participants, we show signal detection for our device to be highly robust. Moreover, via application of source-space modelling, we show that, despite having 5 times fewer sensors, our system exhibits comparable performance to an established cryogenic MEG device. While significant challenges still remain, these developments provide further evidence that OPM-MEG is likely to facilitate a step change for functional neuroimaging. HIGHLIGHTSO_LIA 49-channel whole-head OPM-MEG system is constructed C_LIO_LISystem evaluated via repeat measurements of alpha, beta and gamma oscillations C_LIO_LITwo OPM-helmet designs are contrasted, a flexible (EEG-like) cap and a rigid helmet C_LIO_LIThe rigid helmet offers significant advantages for a viable OPM-MEG device C_LIO_LI49-channel OPM-MEG offers performance comparable to established cryogenic devices C_LI

neuroscience↗

The haemodynamics of the human placenta in utero

We have used MRI to provide important new insights into the function of the human placenta in utero. We have measured slow net flow and high net oxygenation in the placenta in vivo, which are consistent with efficient delivery of oxygen from mother to fetus. Our experimental evidence substantiates previous hypotheses on the effects of spiral artery remodelling in utero, and also indicates rapid venous drainage from the placenta, which is important since the outflow has been largely neglected in the past. Furthermore, beyond Braxton Hicks contractions, which involve the entire uterus, we have identified a new physiological phenomenon, the utero-placental pump, by which the placenta and underlying uterine wall contract independently of the rest of the uterus, expelling maternal blood from the intervillous space.

physiology↗

Pragmatic spatial sampling for wearable MEG arrays

Several new technologies have recently emerged promising new MEG systems in which the sensors can be placed close to the scalp. One such technology, Optically Pumped Magnetometry MEG (OP-MEG) allows for a scalp mounted flexible system that provides field measurements within mm of the scalp surface. A question that arises in developing on-scalp systems, such as OP-MEG scanners, is: how many sensors are necessary to achieve adequate performance/spatial discrimination? There are many factors to consider in answering this question such as the signal to noise ratio (SNR), the locations and depths of the sources of interest, the density of spatial sampling, sensor gain errors (due to interference, subject movement, cross-talk, etc.) and, of course, the desired spatial discrimination. In this paper, we provide simulations which show the impact these factors have on designing sensor arrays for wearable MEG. While OP-MEG has the potential to provide high information content at dense spatial samplings, we find that adequate spatial discrimination of sources (<1cm) can be achieved with relatively few sensors (<100) at coarse spatial samplings (~30mm) at high SNR. Comparable discrimination for traditional cryogenic systems require far more channels by these same metrics. Finally we show that sensor gain errors have the greatest impact on discrimination between deep sources at high SNR.

neuroscience↗

Modulating brain networks with transcranial magnetic stimulation over the primary motor cortex: a concurrent TMS/fMRI study

Stimulating the primary motor cortex (M1) using transcranial magnetic stimulation (TMS) causes unique multisensory experience such as the targeted muscle activity, afferent/reafferent sensory feedback, tactile sensation over the scalp and click sound. Although the human M1 has been intensively investigated using TMS, the experience of the M1 stimulation has not been elucidated at the whole brain. Here, using concurrent TMS/fMRI, we investigated the acute effect of the M1 stimulation of functional brain networks during task and at rest. A short 1Hz train of TMS pulses applied to individuals hand area in the M1 during motor execution or at rest. Employing the independent component analysis (ICA), we showed the M1 stimulation decreased the motor networks activity when the networks were engaged in the task and increased the deactivation of networks when the networks were not involved in the ongoing task. The M1 stimulation induced the activation in the key networks involved in bodily self-consciousness (BSC) including the insular and rolandic operculum systems regardless of states. The degree of activation in these networks was highest at rest compared to during task, showing the state-dependent TMS effect. Furthermore, we demonstrated that the M1 stimulation modulated other domain general networks such as the default mode network and attention network and the inter-network connectivity between these networks. Our results showed that the M1 stimulation induced the widespread changes in the brain at the targeted system as well as non-motor, remote brain networks, specifically related to the BSC. Our findings shed light on understanding the neural mechanism of the complex and multisensory experience of the M1 stimulation.

neuroscience↗

Using optically-pumped magnetometers to measure magnetoencephalographic signals in the human cerebellum

We test the feasibility of an optically pumped magnetometer (OPM)-MEG system for the measurement of human cerebellar activity. We show that the OPM system allows for excellent coverage of this structure by decreasing the average sensor-to-cerebellum distance by around 33% (16mm), compared to a standard MEG helmet. This closer proximity to the cerebellum approximately doubles the signal-to-noise ratio (SNR). As a proof of principle, we used an air-puff stimulus to the eyeball in order to elicit cerebellar evoked and induced responses that are well characterized in non-human models. In three subjects, we observed an evoked component at 50ms post stimulus, which originates in the cerebellum (predominantly ipsilateral). This response was followed by a second component at 100ms post stimulus (predominantly contra-lateral). Sensory stimulation also elicited an event-related broadband spectral power change in the ipsilateral cerebellum at ~100ms in all subjects. We conclude that the OPM-MEG technology offers a promising way to advance the understanding of the information processing mechanisms in the human cerebellum.

neuroscience↗