bioRxiv Science⌕ Search

Biology subjects

Borbath, T.

Publications and source records attributed to Borbath, T..

3 recordsLinked to original sources

ProFit-1D for quantifying J-difference edited data at 3T

Reproducible and accurate fitting of the magnetic resonance spectrum is critical for estimating metabolite concentrations. We have previously developed a fitting software called ProFit-1D which was shown to fit 9.4T semi-LASER data from the human brain with high accuracy and precision. In this study, we adapted ProFit-1D to fit J-difference edited spectra acquired at a clinical field strength of 3T and to assessed its performance in simulated and in vivo data. ProFit-1D was adapted to fit J-difference edited data with alterations to the fitting range to exclude the 1.3 ppm lipid resonance, starting T2 relaxation constants, initial fit parameters, and adaptive spectral baseline determination. The accuracy of ProFit-1D was systematically evaluated on simulated GABA-edited and 2-hydroxyglutarate-edited (2HG-edited) data with different types of in vivo parameter variations and compared to that of LCModel and Gannet, two software commonly used to fit J-difference edited data. The precision of ProFit-1D was also evaluated in GABA-edited spectra acquired in vivo in the occipital cortex (OCC) and medial prefrontal cortex (mPFC) of healthy participants at 3T using subsets of averages and compared to that of LCModel and Gannet. The 2HG fit error was also evaluated for ProFit-1D in 2HG-edited spectra acquired in glioma patients and compared to that of LCModel. Overall, it was found that ProFit-1D generally produced fits with low parameter fit errors across a variety of parameter variations. GABA, glutamate plus glutamine (Glx), and 2HG levels were also more accurately estimated with ProFit-1D than with LCModel and Gannet across different spectral disturbances and simulated concentrations. ProFit-1D was found to be as precise as LCModel and more precise than Gannet in estimating GABA and Glx. 2HG fit errors were 45% lower with ProFit-1D than with LCModel. Thus, ProFit-1D was found to produce high-quality fits to J- difference edited data with high accuracy and precision.

bioengineering↗

Quantitative 2D J-resolved metabolite-cycled semiLASER spectroscopy of metabolites and macromolecules in the human brain at 9.4 T

PurposeWhile two-dimensional (2D) in vivo spectroscopy yields rich information and has been successfully used in clinical trials, it requires a localization scheme that minimizes the impact of chemical shift displacement on J-coupling evolution, a robust frequency drift correction and dedicated processing and quantification methods. Considering these needs this study demonstrates a novel data acquisition and an analysis pipeline to quantify 16 metabolites in mmol/kg in the human brain using a 2D J-resolved metabolite-cycled (MC) semiLASER localization sequence at 9.4 T in the human brain. MethodsMetabolite spectra were acquired in vivo using the newly developed J-resolved MC semiLASER localization sequence with maximum echo sampling (MES) at 9.4 T. In order to account for the underlying macromolecular (MM) spectra in the acquired metabolite spectra, J-resolved MM spectra were acquired using a double inversion recovery (DIR) J-resolved MC semiLASER. Spectral fitting was performed with ProFit 2.0 using a simulated basis set from VesPA tailored to 2D J-resolved semiLASER with MES. Finally, metabolite concentrations were calculated using internal water referencing. ResultsTissue concentrations for 16 metabolites in mmol/kg are reported after correcting for number of protons, tissue content, and relaxation effects of both water and metabolites at 9.4T. Quantification results of spectra considering 8 and 2 averages per TE did not show any significant differences. Conclusion2D spectra of metabolites acquired at 9.4T and 2D MMs acquired at any field strength are presented for the first time. Basis set simulation and quantification of metabolites for metabolite spectra acquired using maximum-echo-sampled 2D J-resolved semiLASER was performed for the first time. The sensitivity in the detection of J-coupled metabolites such as glutamine, glucose or lactate. At ultra-high field, the acquisition duration of 2D MRS can be also substantially reduced since only a very low number of averages per TE are needed.

neuroscience↗

31P Transversal Relaxation Times and Metabolite Concentrations in the Human Brain at 9.4T

A method to estimate phosphorus (31P) transversal relaxation times (T2) of coupled spin systems is demonstrated. Additionally, intracellular and extracellular pH (pHext, pHint) and relaxation corrected metabolite concentrations are reported. Echo time (TE) series of 31P metabolite spectra were acquired using STEAM localization. Spectra were fitted using LCModel with accurately modeled Vespa basis sets accounting for J-evolution of the coupled spin systems. T2s were estimated by fitting a single exponential two-parameter model across the TE series. Fitted inorganic phosphate frequencies were used to calculate pH, and relaxation times were used to determine the brain metabolite concentrations. The method was demonstrated in the healthy human brain at a field strength of 9.4T. T2 relaxation times of ATP and NAD are the shortest between 8 ms and 20 ms, followed by T2s of inorganic phosphate between 25 ms and 50 ms, and PCr with a T2 of 100 ms. Phosphomonoesters and -diesters have the longest T2s of about 130 ms. Measured T2s are comparable to literature values and fit in a decreasing trend with increasing field strengths. Calculated pHs and metabolite concentrations are also comparable to literature values.

neuroscience↗