bioRxiv Science⌕ Search

Biology subjects

Blazejewska, A. I.

Publications and source records attributed to Blazejewska, A. I..

3 recordsLinked to original sources

Temporal evolution and spatial heterogeneity of cerebral cortical-depth profiles of the BOLD-fMRI response

Functional MRI measures brain activity by tracking the associated hemodynamic response, which is shaped by the vascular anatomy. Microscopy studies have shown that the hemodynamic response initiates within the cerebral cortex then spreads upwards to the pial surface, where the largest fMRI signal changes are seen, however responses at the cortical surface exhibit poor neuronal specificity. Motived by this, we characterized the time-evolution of the fMRI response in humans. At some cortical locations the fMRI response peaked at the pial surface but in others it peaked within the cortex, likely due to the sparsity of large pial vessels and the dense capillary bed in middle cortical layers. We observed the earliest response onset in middle cortical depths, which is also the site of thalamocortical input. Standard approaches that aggregate fMRI responses over space and time may therefore lose meaningful information, and "physiologically-informed" strategies may enhance neuronal specificity of fMRI measurements.

neuroscience↗

Differentiating BOLD and non-BOLD signals in fMRI time series using cross-cortical depth delay patterns

Over the past two decades, rapid advancements in magnetic resonance technology have significantly enhanced the imaging resolution of functional Magnetic Resonance Imaging (fMRI), far surpassing its initial capabilities. Beyond mapping brain functional architecture at unprecedented scales, high-spatial-resolution acquisitions have also inspired and enabled several novel analytical strategies that can potentially improve the sensitivity and neuronal specificity of fMRI. With small voxels, one can sample from different levels of the vascular hierarchy within the cerebral cortex and resolve the temporal progression of hemodynamic changes from parenchymal to pial vessels. We propose that this characteristic pattern of temporal progression across cortical depths can aid in distinguishing neurogenic blood-oxygenation-level-dependent (BOLD) signals from typical nuisance factors arising from non-BOLD origins, such as head motion and pulsatility. In this study, we examine the feasibility of applying cross-cortical depth temporal lag (CortiLag) patterns to automatically categorize BOLD and non-BOLD signal components in modern-resolution BOLD-fMRI data. We construct an independent component analysis (ICA)-based framework for fMRI de-noising, analogous to previously proposed multi-echo (ME) ICA, except that here we explore the across-depth instead of across-echo dependence to distinguish BOLD and non-BOLD components. The efficacy of this framework is demonstrated using visual task data at three graded spatiotemporal resolutions (voxel sizes = 1.1, 1.5, and 2.0 mm isotropic at temporal intervals = 1700, 1120, and 928 ms). The proposed CortiLag-ICA framework leverages prior knowledge of the spatiotemporal properties of BOLD-fMRI and serves as an alternative to ME-ICA for cleaning moderate- and high-spatial-resolution fMRI data when multi-echo acquisitions are not available.

neuroscience↗

Slice-direction geometric distortion evaluation and correction with reversed slice-select gradient acquisitions

Accurate spatial alignment of MRI data acquired across multiple contrasts in the same subject is often crucial for data analysis and interpretation, but can be challenging in the presence of geometric distortions that differ between acquisitions. It is well known that single-shot echo-planar imaging (EPI) acquisitions suffer from distortion in the phase-encoding direction due to B0 field inhomogeneities arising from tissue magnetic susceptibility differences and other sources, however there can be distortion in other encoding directions as well in the presence of strong field homogeneities. High-resolution ultrahigh-field MRI typically uses low bandwidth in the slice-encoding direction to acquire thin slices and, when combined with the pronounced B0 inhomogeneities, is prone to an additional geometric distortion in the slice direction as well. Here we demonstrate a presence of this slice distortion in high-resolution 7T EPI acquired with a novel pulse sequence allowing for the reversal of the slice-encoding gradient polarity that enables the acquisition of pairs of images with equal magnitudes of distortion in the slice direction but with opposing polarities. We also show that the slice-direction distortion can be corrected using gradient reversal-based method applying the same software used for conventional corrections of phase-encoding direction distortion.

neuroscience↗