Microfluidic device combining hydrodynamic and dielectrophoretic trapping for the controlled contact between single micro-sized objects and application to adhesion assays

The understanding of cell-cell and cell-matrix interactions via receptor and ligand binding relies on our ability to study the very first events of their contact. Of particular interest is the interaction between a T cell receptor and its cognate peptide-major histocompatibility complex. Indeed analyzing their binding kinetics and cellular avidity in large-scale low-cost and fast cell sorting would largely facilitate the access to cell-based cancer immunotherapies. We thus propose a microfluidic tool able to independently control two types of micro-sized objects, put them in contact for a defined time and probe their adhesion state. The device consists in hydrodynamic traps holding the first type of cells from below against the fluid flow, and a dielectrophoretic system to force the second type of object to remain in contact to the first one. First the device is validated by performing an adhesion frequency assay between fibroblasts and fibronectin coated bead. Then, a study is conducted on the modification of the cellular environment to match the dielectrophoretic technology requirements without modifying the cells viability and interaction functionalities. Finally, we demonstrate the capability of the developed device to put cancer cells and a population of T cells in contact and show the discrimination between specific and non specific interactions based on pairs lifetime.

bioengineering↗

On demand nanoliter sampling probe for collection of brain fluid

Continuous fluidic sampling systems allow collection of brain biomarkers in vivo. Here, we propose a new sampling paradigm, Droplet on Demand (DoD), implemented in a microfabricated neural probe. It allows sampling droplets loaded with molecules from the brain extracellular fluid punctually, without the long transient equilibration periods typical of continuous methods. It uses an accurate fluidic sequence and correct operation is verified by the embedded electrodes. As a proof of concept, we demonstrated the application of this novel approach in vitro and in vivo, to collect glucose in the brain of mice, with a temporal resolution of 1-2 minutes and without transient regime. Absolute quantification of the glucose level in the samples was performed by direct infusion nanoelectrospray ionization Fourier transform mass spectrometry (nanoESI-FTMS). By adjusting the diffusion time and the perfusion volume of DoD, the fraction of molecules recovered in the samples can be tuned to mirror the tissue concentration at accurate points in time. This makes quantification of biomarkers in the brain possible within acute experiments of only 20 to 120 minutes. DoD provides a complementary tool to continuous microdialysis and push-pull sampling probes. The advances allowed by DoD will benefit quantitative molecular studies in the brain, namely for molecules involved in volume transmission or for protein aggregates that form in neurodegenerative diseases over long periods. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=99 SRC="FIGDIR/small/487549v2_ufig1.gif" ALT="Figure 1"> View larger version (33K): org.highwire.dtl.DTLVardef@1edeb56org.highwire.dtl.DTLVardef@f573aforg.highwire.dtl.DTLVardef@7dfd38org.highwire.dtl.DTLVardef@17b7b46_HPS_FORMAT_FIGEXP M_FIG C_FIG

neuroscience↗