bioRxiv Science⌕ Search

Biology subjects

Bayer, C. L.

Publications and source records attributed to Bayer, C. L..

3 recordsLinked to original sources

Pregnancy-Dependent Cardioprotection via GPER Activation in Dahl Salt-Sensitive Rats

BackgroundPreeclampsia is a hypertensive disorder of pregnancy that affects multiple organs, including the heart, increasing long-term cardiovascular risks for both the mother and offspring. While the G protein-coupled estrogen receptor (GPER) has cardioprotective effects, its role in pregnancy-associated cardiac dysfunction, particularly in chronic hypertension, remains unclear, given the significant physiological adaptations that occur during pregnancy, including hormonal fluctuations and hemodynamic changes. This study investigated whether LNS8801, a selective and orally bioavailable GPER agonist, could improve cardiac function in virgin and pregnant Dahl salt-sensitive (SS/Jr) rats, a model of chronic hypertension exacerbated by pregnancy. MethodsFemale Dahl SS/Jr rats, both virgin and pregnant, were randomized into four groups: Virgin + Vehicle, Virgin + LNS8801, Pregnant + Vehicle, and Pregnant + LNS8801. LNS8801 (800 {micro}g/kg/day, given orally) was administered in pregnant rats from gestational day (GD) 9 to 20 and for an equivalent period in virgin controls. Cardiac function was assessed via echocardiography, including speckle-tracking strain analysis and conventional systolic and diastolic parameters. Mean arterial pressure and proteinuria were also measured. ResultsLNS8801 significantly improved cardiac function in pregnant Dahl SS/Jr rats, enhancing global longitudinal, circumferential, and radial strain, as well as increasing systolic function. Additionally, LNS8801 enhanced diastolic function, improving left ventricular compliance (E/A ratio) and early mitral annular velocity (e'), while reducing left ventricular filling pressures (E/e' ratio). In contrast, LNS8801 had no significant effects on cardiac function and blood pressure in virgin Dahl SS/Jr rats, suggesting that pregnancy-related adaptations may enhance GPER-mediated cardioprotection. LNS8801 treatment significantly reduced proteinuria in both virgin and pregnant rats, indicating a pregnancy-independent renal protective effect. ConclusionThis study highlights the importance of pregnancy-specific adaptations in shaping the cardiovascular effects of GPER activation. While LNS8801 demonstrated cardioprotective and antihypertensive benefits in pregnant Dahl SS/Jr rats, its effects were absent in virgin animals, underscoring the influence of the physiological and hormonal environment on GPER-mediated responses. These findings provide a foundation for further exploration of GPER as a therapeutic target for pregnancy-associated cardiovascular dysfunction and preeclampsia, reinforcing the need for pregnancy-specific approaches in drug development.

pharmacology and toxicology↗

Quantifying Molecular Changes in the Preeclamptic Rat Placenta with Targeted Contrast-Enhanced Ultrasound Imaging

PurposeAbnormal placental remodeling is linked to various pregnancy-related diseases, including preeclampsia (PE). This study applies a bicompartmental (BCM) model to quantify molecular expression changes in the placenta, indicative of abnormal placental remodeling, and evaluates the effectiveness of targeted contrast-enhanced ultrasound (T-CEUS) in detecting the abnormal placental vasculature. The BCM model provides high temporal resolution and differentiation of anatomical artery structures within the placenta by analyzing the distribution of contrast agents. MethodsA targeted contrast agent (TCA) composed of gas-filled microbubbles (MB), with a surface-conjugated peptide to target {nu}{beta}3 integrin, a biomarker for angiogenesis, was used for quantifying placental vascular development. CEUS images were acquired from timed pregnant Sprague Dawley rats with experimentally-induced reduced uterine perfusion pressure (RUPP) placental insufficiency. On gestational day (GD) 18 of a 21-day gestation, CEUS images were acquired from both Normal pregnant (NP; n=6) and RUPP (n=6) dams after injection of the TCA. The BCM model was used to estimate the binding dynamics of the TCA, providing a parametric map of the binding constant (Kb) of the placenta. ResultsThe RUPP group showed a significant reduction in the value of Kb compared to the NP group (p < 0.05). A histogram of the placental Kb was compared to alternative analyses (differential target enhancement, dTE and late enhancement, LE) to demonstrate that it can differentiate between anatomical artery structures with a higher contrast-to-background ratio. ConclusionsThe BCM method differentiates molecular changes associated with the abnormal placental development associated with PE. It also reveals more intricate internal anatomical structures of the placenta in comparison to dTE and LE, suggesting that the BCM could enhance early detection and monitoring of PE.

bioengineering↗

Improved Spectral Inversion of Blood Oxygenation due to Reduced Tissue Scattering: Towards NIR-II Photoacoustic Imaging

SignificanceConventional spectral photoacoustic imaging (sPAI) to assess tissue oxygenation (sO2) uses optical wavelengths in the first near infrared window (NIR-I). This limits the maximum imaging depth ([~]1 cm) due to high spectral coloring of biological tissues. AimSecond near infrared or short-wave infrared (NIR-II or SWIR) wavelengths (950-1400 nm) show potential for deep tissue sPAI due to the exponentially reduced tissue scattering and higher maximum exposure threshold (MPE) in this wavelength range. However, to date, a systematic assessment of NIR-II wavelengths for sPAI of tissue sO2 has yet to be performed. ApproachThe NIR-II PA spectra of oxygenated and deoxygenated hemoglobin was first characterized using a phantom. Optimal wavelengths to minimize spectral coloring were identified. The resulting NIR-II PA imaging methods were then validated in vivo by measuring renal sO2 in adult female rats. ResultssPAI of whole blood under a phantom and of circulating renal blood in vivo, demonstrated PA spectra proportional to wavelength-dependent optical absorption. NIR-II wavelengths had a [~]50% decrease in error of spectrally unmixed blood sO2 compared to conventional NIR-I wavelengths. In vivo measurements of renal sO2 validated these findings and demonstrated a [~]30% decrease in error of estimated renal sO2 when using NIR-II wavelengths for spectral unmixing in comparison to NIR-I wavelengths. ConclusionssPAI using NIR-II wavelengths improved the accuracy of tissue sO2 measurements. This is likely due to the overall reduced spectral coloring in this wavelength range. Combined with the increased safe skin exposure fluence limits in this wavelength range, demonstrate the potential to use NIR-II wavelengths for quantitative sPAI of sO2 from deep heterogeneous tissues.

bioengineering↗