bioRxiv Science⌕ Search

Biology subjects

Bashir, R.

Publications and source records attributed to Bashir, R..

9 recordsLinked to original sources

Kinetic Modeling of Target-Amplification-Free CRISPR-Cas-Based Autocatalysis Reactions

CRISPR-Cas-based diagnostics utilize the Cas enzymes trans-cleavage activity to generate signal and have become popular platforms for sensitive nucleic acid detection. Recently, autocatalytic systems have been demonstrated to improve the time to response and sensitivity in some cases. However, mechanistic description of these assays is limited and optimization relies on simple trial-and-error. In this work, we present the first comprehensive kinetic model that integrates all major biochemical processes involved in these assays, including cleavage reactions, nucleic acid equilibrium kinetics, inhibition of trans-cleavage by single-stranded DNA, and degradation of single-stranded reaction components. We discuss the biochemical foundations and implementation of the ordinary differential equation model, which is built for adaptation to different reaction schemes. We use the full model to investigate the role of nucleic acid stability in assay performance for a typical nucleic acid design and show that our model demonstrates inhibition effects consistent with experimental data. We describe the reaction behavior, derive a simplified analytical model and compare its performance to the full analytical model. Finally, we demonstrate tools developed for rapid in silico optimization to guide the rational design of future target-amplification-free CRISPR-Cas-based autocatalysis assays.

bioengineering↗

Amplification-Free Dual-Blocking Autocatalytic CRISPR-Cascade for Atto-Molar DNA Detection with Low Nonspecific Signal

Autocatalytic CRISPR architecture offers amplification-free nucleic acid detection by directly linking target recognition to self-reinforcing ribonucleoprotein (RNP) generation. However, spontaneous background activation remains a key barrier, because strand invasion or unwinding events can initiate unintended amplification and diminish assay specificity. Here, we introduce a dual-blocking CRISPR-Cascade design that independently cages both the guide RNA and trigger DNA, establishing an intrinsic AND gate to raise the effective kinetic barrier for unintended RNP formation. This strategy suppresses leakage by approximately 3- to 18-fold relative to single blocking configurations in full Cascade reactions, while preserving rapid detection (10 min), achieving single-copy sensitivity, and enabling quantitative detection. When paired with a competitive guide RNA decoy, the system further reduces background signals without affecting true target detection. Finally, we demonstrate robust Methicillin-resistant Staphylococcus aureus (MRSA) detection from whole blood in under 40 minutes including the sample purification and extraction. These results establish dual-blocking as a generalizable molecular gating framework for constructing leakage-resistant, amplification-free CRISPR systems suitable for rapid and decentralized diagnostics. SignificanceAmplification-free CRISPR diagnostics are often presented as simple positive feedback circuits, but most existing systems treat leakage, defined as target independent background activation that arises when blocked CRISPR components spontaneously form active ribonucleoprotein (RNP), as an unavoidable side effect rather than as a designable property. In particular, prior work has not explicitly accounted for two key sources of background signal in autocatalytic assays: Cas driven unwinding of blocked constructs and transient breathing of nucleic acid duplexes that intermittently expose trigger sites. Our study directly analyzes these leakage pathways in the context of switchable-cage-gRNA (scgRNA) and Cascade probe design and shows that blocking a single component is fundamentally vulnerable to both enzyme-driven strand invasion and equilibrium breathing. By contrast, we introduce a dual-blocking strategy in which both the guide RNA and the trigger DNA are gated. We further add a decoy guide RNA that competes for Cas12a. This multi-layer architecture demonstrates that robust amplification-free operation requires several coordinated barriers rather than a single switch, providing a new design principle for constructing self-amplifying CRISPR circuits with low background and robust signal-to-noise ratio.

molecular biology↗

Highly localized chemical sampling at sub-second temporal resolution enabled with a silicon nanodialysis platform at exceedingly slow flows.

Microdialysis (MD) is a versatile and powerful technique for chemical profiling of biological tissues and is widely used for quantification of neurotransmitters, neuropeptides, metabolites, biomarkers, and drugs in the central nervous system as well as in dermatology, ophthalmology, and in pain research. However, MD performance is severely limited by fundamental tradeoffs between chemical sensitivity, spatial resolution, and temporal response. Here, by using wafer-scale silicon microfabrication, we develop and demonstrate a nanodialysis (ND) sampling probe that enables highly localized chemical sampling with 100m spatial resolution and sub-second temporal resolution at high recovery rates. These performance metrics, which are 100X-1000X superior to existing MD approaches, are enabled by a 100X reduction of the microfluidic channel cross-section, a corresponding drastic 100X reduction of flow rates to exceedingly slow few nL/min flows, and integration of a nanometer-thin nanoporous membrane with high transport flux into the probe sampling area. Miniaturized ND probes may allow for the minimally invasive and highly localized sampling and chemical profiling in live biological tissues with unprecedented spatio-temporal resolution for clinical, biomedical, and pharmaceutical applications.

bioengineering↗

Engineering 3D neuronal networks with directional endogenous neuronal plasticity pathways

The forward engineering of the structure and function of three-dimensional millimeter to centimeter scale living Neuronal Tissue Mimics (NTMs) can advance many engineering and biomedical applications. While hydrogels and 3D printing have achieved major breakthroughs in the development of cm-scale neural tissues that mimic structural morphologies in native neural networks, controlling and programming the resulting function of these NTMs have remained elusive. In this work, using human embryonic stem cell derived optogenetic neurons, we report the in-situ formation of the NTMs on a 2-dimensional micro electrode array with an intimate electrical contact between the electrodes and the tissue. These NTMs were optimized during the differentiation phase of the cells to enrich for neuronal populations that expressed receptors responsible for activating spike-timing dependent plasticity (STDP). Using an optical stimulation regiment with millisecond temporal and micrometer spatial resolution, we were able to program the otherwise omnidirectional spontaneous firing in the NTMs to demonstrate directional firing across different shapes of the NTMs. Our work can pave the way for developing cellular based computational devices, bio-processors, and biological memories.

bioengineering↗

Improved performance of biohybrid muscle-based bio-bots doped with piezoelectric boron nitride nanotubes

Biohybrid robots, or bio-bots, integrate living and synthetic materials following a synergistic strategy to acquire some of the unique properties of biological organisms, like adaptability or bio-sensing, which are difficult to obtain exclusively using artificial materials. Skeletal muscle is one of the preferred candidates to power bio-bots, enabling a wide variety of movements from walking to swimming. Conductive nanocomposites, like gold nanoparticles or graphene, can provide benefits to muscle cells by improving the scaffolds mechanical and conductive properties. Here, we integrate boron nitride nanotubes (BNNTs), with piezoelectric properties, in muscle-based bio-bots and demonstrate an improvement in their force output and motion speed. We provide a full characterization of the BNNTs, and we confirm their piezoelectric behavior with piezometer and dynamometer measurements. We hypothesize that the improved performance is a result of an electric field generated by the nanocomposites due to stresses produced by the cells during differentiation, which in turns improves their maturation. We back this hypothesis with finite element simulations supporting that this stress can generate a non-zero electric field within the matrix. With this work, we show that the integration of nanocomposite into muscle-based bio-bots can improve their performance, paving the way towards stronger and faster bio-hybrid robots.

bioengineering↗

Empowering Engineered Muscle in Biohybrid Pump by Extending Connexin 43 Duration with Reduced Graphene Oxides

Engineered skeletal muscle act as therapeutics invaluable to treat injured or diseased muscle and a "living" material essential to assemble biological machinery. For normal development, skeletal myoblasts should express connexin 43, one of the gap junction proteins that promote myoblast fusion and myogenesis, during the early differentiation stage. However, myoblasts cultured in vitro often down-regulate connexin 43 before differentiation, limiting myogenesis and muscle contraction. This study demonstrates that tethering myoblasts with reduced graphene oxide (rGO) slows connexin 43 regression during early differentiation and increases myogenic mRNA synthesis. The whole RNA sequencing also confirms that the rGO on cells increases regulator genes for myogenesis, including troponin, while decreasing negative regulator genes. The resulting myotubes generated a three-fold larger contraction force than the rGO-free myotubes. Accordingly, a valveless biohybrid pump assembled with the rGO-tethered muscle increased the fluid velocity and flow rate considerably. The results of this study would provide an important foundation for developing physiologically relevant muscle and powering up biomachines that will be used for various bioscience studies and unexplored applications.

bioengineering↗

Rapid SARS-CoV-2 Detection and Classification Using Phase Imaging with Computational Specificity

Efforts to mitigate the COVID-19 crisis revealed that fast, accurate, and scalable testing is crucial for curbing the current impact and that of future pandemics. We propose an optical method for directly imaging unlabeled viral particles and using deep learning for detection and classification. An ultrasensitive interferometric method was used to image four virus types with nanoscale optical pathlength sensitivity. Pairing these data with fluorescence images for ground truth, we trained semantic segmentation models based on U-Net, a particular type of convolutional neural network. The trained network was applied to classify the viruses from the interferometric images only, containing simultaneously SARS-CoV-2, H1N1 (influenza-A), HAdV (adenovirus), and ZIKV (Zika). Remarkably, due to the nanoscale sensitivity in the input data, the neural network was able to identify SARS-CoV-2 vs. the other viruses with 96% accuracy. The inference time for each image is 60 ms, on a common graphic processing unit. This approach of directly imaging unlabeled viral particles may provide an extremely fast test, of less than a minute per patient. As the imaging instrument operates on regular glass slides, we envision this method as potentially testing on patient breath condensates. The necessary high throughput can be achieved by translating concepts from digital pathology, where a microscope can scan hundreds of slides automatically. One Sentence SummaryThis work proposes a rapid (<1 min.), label-free testing method for SARS-CoV-2 detection, using quantitative phase imaging and deep learning.

bioengineering↗

Computationally assisted design and selection of maneuverable biological walking machines

The intriguing opportunities enabled by the use of living components in biological machines have spurred the development of a variety of muscle-powered bio-hybrid robots in recent years. Among them, several generations of bio-hybrid walkers have been established as reliable platforms to study untethered locomotion. However, despite these advances, such technology is not mature yet, and major challenges remain. This study takes steps to address two of them: the lack of systematic design approaches, common to bio-hybrid robotics in general, and in the case of bio-hybrid walkers specifically, the lack of maneuverability. We then present here a dual-ring biobot, computationally designed and selected to exhibit robust forward motion and rotational steering. This dual-ring biobot consists of two independent muscle actuators and a 4-legged scaffold asymmetric in the fore/aft direction. The integration of multiple muscles within its body architecture, combined with differential electrical stimulation, allows the robot to maneuver. The dual-ring robot design is then fabricated and experimentally tested, confirming computational predictions and turning abilities. Overall, our design approach based on modeling, simulation, and fabrication exemplified in this robot represents a route to efficiently engineer biological machines with adaptive functionalities.

bioengineering↗

Rapid Isothermal Amplification and Portable Detection System for SARS-CoV-2

The COVID-19 pandemic provides an urgent example where a gap exists between availability of state-of-the-art diagnostics and current needs. As assay details and primer sequences become widely known, many laboratories could perform diagnostic tests using methods such as RT-PCR or isothermal RT-LAMP amplification. A key advantage of RT-LAMP based approaches compared to RT-PCR is that RT-LAMP is known to be robust in detecting targets from unprocessed samples. In addition, RT-LAMP assays are performed at a constant temperature enabling speed, simplicity, and point-of-use testing. Here, we provide the details of an RT-LAMP isothermal assay for the detection of SARS-CoV-2 virus with performance comparable to currently approved tests using RT-PCR. We characterize the assay by introducing swabs in virus spiked synthetic nasal fluids, moving the swab to viral transport medium (VTM), and using a volume of that VTM for performing the amplification without an RNA extraction kit. The assay has a Limit-of-Detection (LOD) of 50 RNA copies/L in the VTM solution within 20 minutes, and LOD of 5000 RNA copies/L in the nasal solution. Additionally, we show the utility of this assay for real-time point-of-use testing by demonstrating detection of SARS-CoV-2 virus in less than 40 minutes using an additively manufactured cartridge and a smartphone-based reader. Finally, we explore the speed and cost advantages by comparing the required resources and workflows with RT-PCR. This work could accelerate the development and availability of SARS-CoV-2 diagnostics by proving alternatives to conventional laboratory benchtop tests. Significance StatementAn important limitation of the current assays for the detection of SARS-CoV-2 stem from their reliance on time- and labor-intensive and laboratory-based protocols for viral isolation, lysis, and removal of inhibiting materials. While RT-PCR remains the gold standard for performing clinical diagnostics to amplify the RNA sequences, there is an urgent need for alternative portable platforms that can provide rapid and accurate diagnosis, potentially at the point-of-use. Here, we present the details of an isothermal amplification-based detection of SARS-CoV-2, including the demonstration of a smartphone-based point-of-care device that can be used at the point of sample collection.

bioengineering↗