bioRxiv Science⌕ Search

Biology subjects

Bamber, J.

Publications and source records attributed to Bamber, J..

3 recordsLinked to original sources

Evaluating diversionary feeding as a method to resolve conservation conflicts in a recovering ecosystem

1. The recovery of mammalian predators of conservation concern in Europe is a success story, but their impact on some prey species of conservation concern may cause conservation dilemmas. This calls for effective intervention strategies that mitigate predator impacts without compromising their recovery. 2. We evaluated diversionary feeding as a management intervention tool to reduce depredation on nests of rapidly declining Western capercaillies in Scotland. We studied the influence of diversionary feeding provision on the fates of artificial nests deployed using a replicated and representative randomised landscape-scale experiment. This comprised 30 paired control (no diversionary feeding) and treatment (diversionary feeding applied) sites, 60 in total, each containing six artificial nests distributed across 600 km2. The experiment was replicated over two years, and in the second year, the control-treatment pairs were reversed, yielding 60 treatment and 60 control sites and 720 artificial nests. 3. Diversionary feeding substantially reduced depredation of artificial nests, translating into an 83% increase in predicted nest survival over 28 days of incubation. The increase in survival was mostly accounted for by a reduction in the probability that a pine marten, the main nest predator, consumed or cached eggs. Diversionary food also significantly reduced nest predation by badgers, although the magnitude of this effect varied by year. 4. Diversionary feeding is an easily employable method shown in this study to reduce predator impact (functional) without lethal (numerical) intervention. Managers should proceed with its application for conserving capercaillie in Scotland without delay.

ecology↗

Photoacoustic imaging for the prediction and assessment of response to radiotherapy in vivo

Radiotherapy is commonly used for cancer therapy, although its efficacy is reduced in hypoxic regions of tumours. Photoacoustic imaging (PAI) is an emergent, non-invasive imaging technique that allows the measurement of blood oxygen saturation (sO2) which inversely correlates with hypoxia in tissue. The potential use of PAI as a prognostic tool for radiotherapy outcome was investigated in a head and neck cancer model in vivo. PAI was performed before delivering a single fraction (10, 20 or 30 Gy) treatment. The results show that tumours with pre-treatment higher blood sO2 responded better than those with lower levels in the 10 and 20 Gy groups. For the 30 Gy group, treatment response was independent of blood sO2. The haemoglobin content of the tumours was not correlated with their response to any of the radiation doses studied. Changes in sO2, monitored at 24 h and 96 h following 10 and 20 Gy doses, showed that tumours that were subsequently unresponsive to treatment had an increase in blood sO2 at both time points compared to those which subsequently regressed after radiotherapy. The results suggest that sO2 values measured by photoacoustic imaging can be used before, and shortly after, irradiation to predict subsequent treatment response.

biophysics↗

Quantitative photoacoustic imaging study of tumours in vivo

Photoacoustic imaging (PAI) provides information on haemoglobin levels and blood oxygenation (sO2). To facilitate assessment of the variability in sO2 and haemoglobin in tumours, for example in response to therapies, the baseline variability of these parameters was evaluated in subcutaneous head and neck tumours in mice, using a PAI system (MSOT-inVision-256TF). Tumours of anaesthetized animals (midazolam-fentanyl-medetomidine) were imaged for 75 minutes; in varying positions; and repeatedly over 6 days. An increasing linear trend for average tumoural haemoglobin and blood sO2 was observed, when imaging over 75 minutes. There were no significant differences in these temporal trends, when re-positioning tumours. A negative correlation was found between the percent decrease in blood sO2 over 6 days and tumour growth rate. This paper shows the potential of PAI to provide baseline data for assessing the significance of intra- and inter-tumoural variations that may eventually have value for predicting and/or monitoring cancer treatment response.

biophysics↗