bioRxiv Science⌕ Search

Biology subjects

Baez, D.

Publications and source records attributed to Baez, D..

2 recordsLinked to original sources

A voltage-step method for detecting high-frequency transient current components in deep brain tissue: preliminary in vivo measurements in rats

A test technique for measuring high-frequency transient current components in deep brain tissue is presented. The technique applies a voltage pulse with a high value in dV/dt, generating a corresponding current pulse with high dI/dt that can elicit measurable transient current responses from the electrode-tissue interface and adjacent brain tissue; responses are analyzed in the frequency domain by Fast Fourier Transform at a 200 kHz sampling frequency. The method was motivated by prior evidence that ferritin and neuromelanin in catecholaminergic tissue may support high-frequency conduction properties that have not previously been characterized in vivo. The protocol was applied in 277 measurements across five Sprague Dawley rats at cortical and basal ganglia locations in different locations in the brain. Preliminary spectral results show differences between catecholaminergic regions and cortical tissue that support further development and validation of the method.

neuroscience↗

Differential Tissue Coupled Powering for Battery-Free Injectable Electroceuticals

Electroceutical implants that deliver targeted neural stimulation have shown therapeutic potential for a wide range of neurological and peripheral disorders, yet wirelessly powering ultra-miniaturized, fully injectable systems remains a critical challenge. Here we report a Thread-like Injectable Neural TechnologY (TINY), powered via a differential tissue-coupled powering (DTCP) scheme. DTCP employs mid-frequency differential potentials applied across external electrodes on a compact, wearable transmitter to deliver energy through tissue to an ultra-miniaturized, thread-like implant that integrates a custom ASIC and PEDOT-coated receiver and stimulation electrodes. Benchtop experiments in agar phantoms characterize the power-transfer efficiency (PTE) and reveal that PTE increases with implant length while maintaining strong tolerance to angular misalignment. In vivo tests in rat hindlimbs further demonstrate wireless activation of the sciatic nerve through tissue at centimeter-scale depths, confirming effective transcutaneous energy delivery for neurostimulation. A 20-day implantation study shows stable positioning of the device with minimal tissue response, indicating excellent chronic compatibility. These findings address long-standing challenges in wirelessly powering injectable electroceuticals and establish DTCP as a scalable and alignment-robust powering strategy for future minimally invasive neuromodulation therapies.

bioengineering↗