bioRxiv Science⌕ Search

Biology subjects

Babataheri, A.

Publications and source records attributed to Babataheri, A..

6 recordsLinked to original sources

Interplay of actin nematodynamics and anisotropic tension controls endothelial mechanics

Blood vessels expand and contract actively, while continuously experiencing dynamic external stresses from the blood flow. The mechanical response of the vessel wall is that of a composite material: its mechanical properties depend on a diverse set of cellular mechanical components, which change dynamically as cells respond to external stress. Mapping the relationship between these underlying cellular processes and emergent tissue mechanics is an on-going challenge, in particular in endothelial cells. Here we use a microstretcher mimicking the native environment of blood vessels to assess both the mechanics and cellular dynamics of an endothelial tube in response to a physiological increase in luminal pressure. The characterization of the instantaneous monolayer elasticity reveals a strain-stiffening, actin-dependent and substrate-responsive behavior. In response to a maintained pressure increase, the tissue displays a fluid-like expansion, accompanied by the reorientation of cell shape and of actin fibers. This actin-driven reorientation depends on focal adhesions and adherens junctions, two key mechanosensors. We introduce a mechanical model coupling actin fiber nematodynamics with active and elastic tension generation by actin fibers in the endothelium, which recapitulates the response to pressure of endothelial tubes.

biophysics↗

1D confinement mimicking microvessel geometry controls pericyte shape and motility

Pericytes are mural cells of the microvasculature, characterised by their elongated distinct shape. Pericytes span along the axis of the vessels they adhere to, therefore they experience extreme lateral and longitudinal confinement. Pericyte shape is key for their function during vascular regulation and their spatial distribution is established by cell migration during the embryonic stage and maintained through controlled motility in the adult. However, how pericyte morphology is associated with migration and function remains unknown. We use micropatterns to mimic pericyte adhesion to vessels, and to reproduce in vitro the shapes adopted by pericytes in vivo. We show that lateral confinement controls cell shape and produces in vivo-like phenotype. Modelling the pericyte as an incompressible linear elastic material predicts strain and shape of pericytes as a function of lateral confinement. Pericyte kinetics on both laterally confining lanes, and longitudinally constraining motifs is described by dry friction theory. Pericytes are capable of crossing gaps of different sizes. The percentage of crossings is correctly predicted by the likelihood of a fluctuating system to overcome an energy barrier. Our joint experimental and theoretical approach demonstrates the effect of in vivo-like geometrical confinement on pericyte morphology and migration which is accurately described by dry friction theory.

biophysics↗

Local compression of the root in a microfluidic device triggers a calcium signal

Throughout their life, plant root are submitted to mechanical stresses due to pressure exerted by the soil. So far, few studies addressed root cell deformation and calcium signaling elicited by soil compression. In this study, we designed a microchip inspired by pneumatic microvalve concept in order to deliver a lateral pressure to the root of a plant expressing the RGECO1-mTurquoise calcium reporter. Lateral pressure applied on the root induced a moderate elastic deformation of root cortical cells and elicited a multicomponent calcium signal at the onset of the pressure pulse, followed by a second one at the release of the pressure. This indicates that straining rather than stressing of tissues is relevant to trigger the calcium signal. The calcium elevation was restricted to the tissue under pressure and did not propagate. Additionally, the calcium signals exhibited a remarkable attenuation upon repetitive stimulations. Highlights- A microvalve concept mimicking lateral soil pressure was developed. - Non-damaging lateral compression of the root induces an elastic deformation of cortical cells. - A multicomponent calcium signal is elicited at the onset of a pressure pulse and upon release of the pressure. - Straining rather than stressing of tissues is relevant to trigger the calcium signal. - The calcium signal is localized at the tissue under pressure and does not propagate. - Calcium signals exhibit a remarkable attenuation upon repetitive stimulations.

plant biology↗

PPP2R1A Regulates Migration Persistence through the WAVE Shell Complex

The RAC1-WAVE-Arp2/3 signaling pathway generates branched actin networks that power lamellipodium protrusion of migrating cells. Feedback is thought to control protrusion lifetime and migration persistence, but its molecular circuitry remains elusive. Using proteomics, we identified PPP2R1A among proteins differentially associated with the WAVE complex subunit ABI1 when RAC1 was activated and downstream generation of branched actin was blocked. PPP2R1A was found to associate at the lamellipodial edge with a novel form of WAVE complex, the WAVE Shell Complex (WSC), that contains NHSL1 instead of the Arp2/3 activating subunit WAVE as in the canonical WAVE Regulatory Complex (WRC). PPP2R1A was required for persistence in random and directed migration assays and for RAC1-dependent actin polymerization in cell extracts. PPP2R1A requirement was abolished by NHSL1 depletion. PPP2R1A mutations found in tumors impaired WSC binding and migration regulation, suggesting that this novel function of PPP2R1A is critical for its tumor suppressor activity.

cell biology↗

Luminal Flow Actuation Generates Coupled Shear and Strain in a Microvessel-on-Chip

In the microvasculature, blood flow-derived forces are key regulators of vascular structure and function. Consequently, the development of hydrogel-based microvessel-on-chip systems that strive to mimic the in vivo cellular organization and mechanical environment has received great attention in recent years. However, despite intensive efforts, current microvessel- on-chip systems suffer from several limitations, most notably failure to produce physiologically relevant wall strain levels. In this study, a novel microvessel-on-chip based on the templating technique and using luminal flow actuation to generate physiologically relevant levels of wall shear stress and circumferential stretch is presented. Normal forces induced by the luminal pressure compress the surrounding soft collagen hydrogel, dilate the channel, and create large circumferential strain. The fluid pressure gradient in the system drives flow forward and generates realistic pulsatile wall shear stresses. Rigorous characterization of the system reveals the crucial role played by the poroelastic behavior of the hydrogel in determining the magnitudes of the wall shear stress and strain. The experimental measurements are combined with an analytical model of flow in both the lumen and the porous hydrogel to provide an exceptionally versatile user manual for an application-based choice of parameters in microvessels-on-chip. This unique strategy of flow actuation adds a dimension to the capabilities of microvessel-on-chip systems and provides a more general framework for improving hydrogel-based in vitro engineered platforms. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=80 SRC="FIGDIR/small/439271v1_ufig1.gif" ALT="Figure 1"> View larger version (23K): org.highwire.dtl.DTLVardef@1a4fed5org.highwire.dtl.DTLVardef@15680f4org.highwire.dtl.DTLVardef@2c2a6dorg.highwire.dtl.DTLVardef@1955f52_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗

Single-cell immuno-mechanics: rapid viscoelastic changes are a hallmark of early leukocyte activation.

To accomplish their critical task of removing infected cells and fighting pathogens, leukocytes activate by forming specialized interfaces with other cells. Using an innovative micropipette rheometer, we show in three different cell types that when stimulated by microbeads mimicking target cells, leukocytes become up to ten times stiffer and more viscous. These mechanical changes initiate within seconds after contact and evolve rapidly over minutes. Remarkably, leukocyte elastic and viscous properties evolve in parallel, preserving a well-defined ratio that constitutes a mechanical signature specific to each cell type. The current results indicate that simultaneously tracking both elastic and viscous properties during an active cell process provides a new way to investigate cell mechanical processes. Our findings also suggest that dynamic immuno-mechanical measurements provide an identifier of leukocyte type and an indicator of the cells state of activation.

biophysics↗