bioRxiv Science⌕ Search

Biology subjects

Andersson, J. L. R.

Publications and source records attributed to Andersson, J. L. R..

8 recordsLinked to original sources

Internally-consistent and fully-unbiased multimodal MRI brain template construction from UK Biobank: Oxford-MM

Anatomical MRI templates of the brain are essential to group-level analyses and image processing pipelines, as they provide a reference space for spatial normalisation. While it has become common for studies to acquire multimodal MRI data, many templates are still limited to one type of modality, usually either scalar or tensor-based. Aligning each modality in isolation does not take full advantage of the available complementary information, such as strong contrast between tissue types in structural images, or axonal organisation in the white matter in diffusion tensor images. Most existing strategies for multimodal template construction either do not use all modalities of interest to inform the template construction process, or do not use them in a unified framework. Here, we present multimodal, cross-sectional templates constructed from UK Biobank data: the OMM-1 template, and age-dependent templates for each year of life between 45 to 81. All templates are fully unbiased to represent the average shape of the populations they were constructed from, and internally consistent through jointly informing the template construction process with T1, T2-FLAIR and DTI data. The OMM-1 template was constructed with a multi-resolution, iterative approach using 240 individuals in the 50-55 year age range. The age-dependent templates were estimated using a Gaussian Process, which describes the change in average brain shape with age in 37,330 individuals. All templates show excellent contrast and alignment within and between modalities. The global brain shape and size is not preconditioned on existing templates, although maximal possible compatibility with MNI-152 space was maintained through rigid alignment. We showed benefits in registration accuracy across two datasets (UK Biobank and HCP), when using the OMM-1 as the template compared with FSLs MNI-152 template, and found that the use of age-dependent templates further improved accuracy to a small but detectable extent. All templates are publicly available and can be used as a new reference space for uni- or multimodal spatial alignment.

neuroscience↗

MMORF - FSL's MultiMOdal Registration Framework

We present MMORF--FSLs MultiMOdal Registration Framework--a newly released nonlinear image registration tool designed primarily for application to MRI images of the brain. MMORF is capable of simultaneously optimising both displacement and rotational transformations within a single registration framework by leveraging rich information from multiple scalar and tensor modalities. The regularisation employed in MMORF promotes local rigidity in the deformation, and we have previously demonstrated how this effectively controls both shape and size distortion, and leads to more biologically plausible warps. The performance of MMORF is benchmarked against three established nonlinear registration methods--FNIRT, ANTs and DR-TAMAS--across four domains: FreeSurfer label overlap, DTI similarity, task-fMRI cluster mass, and distortion. Results show that MMORF performs as well as or better than all other methods across every domain--both in terms of accuracy and levels of distortion. MMORF is available as part of FSL, and its inputs and outputs are fully compatible with existing workflows. We believe that MMORF will be a valuable tool for the neuroimaging community, regardless of the domain of any downstream analysis, providing state-of-the-art registration performance that integrates into the rich and widely adopted suite of analysis tools in FSL.

neuroscience↗

Denoising Diffusion MRI: Considerations and implications for analysis

Development of diffusion MRI (dMRI) denoising approaches has experienced considerable growth over the last years. As noise can inherently reduce accuracy and precision in measurements, its effects have been well characterised both in terms of uncertainty increase in dMRI-derived features and in terms of biases caused by the noise floor, the smallest measurable signal given the noise level. However, gaps in our knowledge still exist in objectively characterising dMRI denoising approaches in terms of both of these effects and assessing their efficacy. In this work, we reconsider what a denoising method should and should not do and we accordingly define criteria to characterise the performance. We propose a comprehensive set of evaluations, including i) benefits in improving signal quality and reducing noise variance, ii) gains in reducing biases and the noise floor and improving, iii) preservation of spatial resolution, iv) agreement of denoised data against a gold standard, v) gains in downstream parameter estimation (precision and accuracy), vi) efficacy in enabling noise-prone applications, such as ultra-high-resolution imaging. We further provide newly acquired complex datasets (magnitude and phase) with multiple repeats that sample different SNR regimes to highlight performance differences under different scenarios. Without loss of generality, we subsequently apply a number of exemplar patch-based denoising algorithms to these datasets, including Non-Local Means, Marchenko-Pastur PCA (MPPCA) in the magnitude and complex domain and NORDIC, and compare them with respect to the above criteria and against a gold standard complex average of multiple repeats. We demonstrate that all tested denoising approaches reduce noise-related variance, but not always biases from the elevated noise floor. They all induce a spatial resolution penalty, but its extent can vary depending on the method and the implementation. Some denoising approaches agree with the gold standard more than others and we demonstrate challenges in even defining such a standard. Overall, we show that dMRI denoising performed in the complex domain is advantageous to magnitude domain denoising with respect to all the above criteria.

neuroscience↗

Sampling strategies and integrated reconstruction for reducing distortion and boundary slice aliasing in high-resolution 3D diffusion MRI

PurposeTo develop a new method for high-fidelity, high-resolution 3D multi-slab diffusion MRI with minimal distortion and boundary slice aliasing. MethodsOur method modifies 3D multi-slab imaging to integrate blip-reversed acquisitions for distortion correction and oversampling in the slice direction (kz) for reducing boundary slice aliasing. Our aim is to achieve robust acceleration to keep the scan time the same as conventional 3D multi-slab acquisitions, in which data are acquired with a single direction of blip traversal and without kz-oversampling. We employ a two-stage reconstruction. In the first stage, the blip-up/down images are respectively reconstructed and analyzed to produce a field map for each diffusion direction. In the second stage, the blip-reversed data and the field map are incorporated into a joint reconstruction to produce images that are corrected for distortion and boundary slice aliasing. ResultsWe conducted experiments at 7T in six healthy subjects. Stage 1 reconstruction produces images from highly under-sampled data (R=7.2) with sufficient quality to provide accurate field map estimation. Stage 2 joint reconstruction substantially reduces distortion artifacts with comparable quality to fully-sampled blip-reversed results (2.4x scan time). Whole-brain in-vivo results acquired at 1.05mm isotropic resolution demonstrate improved anatomical fidelity compared to conventional 3D multi-slab imaging. Data demonstrate good reliability and reproducibility of the proposed method over multiple subjects. ConclusionThe proposed acquisition and reconstruction framework provide major reductions in distortion and boundary slice aliasing for 3D multi-slab diffusion MRI without increasing the scan time. This method has the potential to provide high-quality, high-resolution diffusion MRI.

neuroscience↗

The Forget-Me-Not dHCP study: 7 Tesla high resolution diffusion imaging in the unfixed post-mortem neonatal brain

Diffusion MRI of the neonatal brain allows investigation of the organisational structure of maturing fibres during brain development. Post-mortem imaging has the potential to achieve high resolution by using long scan times, enabling precise assessment of small structures. The Forget-Me-Not study, part of the Developing Human Connectome Project (dHCP), aims to acquire and publicly distribute high-resolution diffusion MRI data for unfixed post-mortem neonatal brain at 7T with a custom-built head coil. This paper describes how the study addressed logistical, technical and ethical challenges relating to recruitment pipeline, care pathway, tissue preservation, scan setup and protocol optimisation. Results from the first subject recruited to the study demonstrate high-quality diffusion MRI data. Preliminary voxel-wise and tractography-based analyses are presented for the cortical plate, subplate and white matter pathways, with comparison to age-matched in vivo dHCP data. These results demonstrate that high quality post-mortem data can be acquired and provide a sensitive means to explore the developing human brain, as well as altered diffusion properties consistent with post-mortem changes, at high resolution.

bioengineering↗

Neurofeedback fMRI in the motor system elicits bi-directional changes in activity and white-matter structure in the healthy adult human brain

Neurofeedback can be used to alter brain activity and is therefore an attractive tool for neuromodulation in clinical contexts. Different contexts might call for different patterns of activity modulation. For example, following stroke, alternative therapeutic strategies could involve up or down-regulation of activity in the ipsilateral motor cortex. However, effects of such strategies on activity and brain structure are unknown. In a proof of concept study in healthy individuals, we showed that fMRI neurofeedback can be used to drive activity up or down in ipsilateral motor cortex during hand movement. Given evidence for activity-dependent white matter plasticity, we also tested effects of activity modulation on white matter microstructure using diffusion tensor imaging (DTI). We show rapid opposing changes in corpus callosum microstructure that depend on the direction of activity modulation. Bidirectional modulation of ipsilateral motor cortex activity is therefore possible, and results not only in online changes in activity patterns, but also in changes in microstructure detectable 24 hours later.

neuroscience↗

Confound modelling in UK Biobank brain imaging

Dealing with confounds is an essential step in large cohort studies to address problems such as unexplained variance and spurious correlations. UK Biobank is a powerful resource for studying associations between imaging and nonimaging measures such as lifestyle factors and health outcomes, in part because of the large subject numbers. However, the resulting high statistical power also raises the sensitivity to confound effects, which therefore have to be carefully considered. In this work we describe a set of possible confounds (including non-linear effects and interactions) that researchers may wish to consider for their studies using such data. We include descriptions of how we can estimate the confounds, and study the extent to which each of these confounds affects the data, and the spurious correlations that may arise if they are not controlled. Finally, we discuss several issues that future studies should consider when dealing with confounds.

neuroscience↗

High resolution nonlinear registration with simultaneous modelling of intensities

This paper describes and evaluates FMRIBs nonlinear image registration tool (FNIRT), that is part of the FMRIB software library (FSL). It is a small deformation framework using sum of squared differences (SSD) as its cost function and Gauss-Newton for minimisation. The framework uses a joint shape and intensity model that attempts to explain the observed differences between two images in terms of having different shape and/or contrast, being differently affected by intensity bias-fields etc. Thus the estimation of the warps will be relatively unaffected by intensity differences that would otherwise violate the assumptions behind the SSD cost function. It uses a projection onto a manifold defined by a specified range of allowed Jacobian determinants to ensure that the warps are diffeomorphic. The utility of the model is demonstrated on a variety of simulated and experimental data with good results. FNIRT is also quantitatively evaluated using previously published datasets consisting of scans from multiple subjects, all with anatomically defined brain regions that are manually outlined. In this evaluation FNIRT performs well in comparison to previously published results with other registration algorithms.

neuroscience↗