bioRxiv Science⌕ Search

Biology subjects

Altekoester, C.

Publications and source records attributed to Altekoester, C..

2 recordsLinked to original sources

Evaluation of Neuronal Activation Thresholds for Low-Frequency Electromagnetic Exposure Using Morphologically Realistic Neuron Models

International guidelines for low-frequency electromagnetic field exposure (LF EMF) are primarily intended to prevent substantiated adverse effects. In the frameworks, limits on internal electric fields are linked to external exposure levels through computational dosimetry. However, the relationship between internal electric fields and these adverse effects remains incompletely understood. In particular, current approaches often overlook the morphological complexity and diversity of cortical neurons, which may limit the realism of neuronal activation estimates used to support these assessments. This study evaluates LF EMF-induced neural activation using 25 morphologically realistic neuron models spanning all cortical layers, embedded within 11 detailed human head models. The internal electric fields were simulated for uniform magnetic field exposures (100 Hz-100 kHz) along the three anatomical directions, and excitation thresholds were computed using a multi-scale framework combining voxel-based dosimetry with biophysical neuron simulations. A real-world exposure scenario involving a child near an acousto-magnetic article-surveillance deactivator was also analyzed. Thresholds varied across cell type, morphology, cortical location, subject anatomy, frequency, and exposure direction, with L2/3 pyramidal, L4 basket, and L5 thick-tufted pyramidal cells showing the lowest thresholds. Despite this variability, all simulated thresholds were conservative with respect to the basic restrictions and dosimetric reference limits set by IEEE ICES and ICNIRP. The smallest margin occurred at 100 kHz, where the threshold remained a factor of 2.8 above the corresponding limit. These findings indicate that current LF EMF exposure limits remain conservative when evaluated using highly detailed, morphology-based CNS activation models.

neuroscience↗

Action Potential Threshold Variability for Different Electrostimulation Models and the Impact on Occupational Exposure Limit Values

Occupational exposure limit values (ELVs) for body internal electric fields can be derived from thresholds for action potential generation. These thresholds can be calculated with electrostimulation models. The spatially extended nonlinear node model (SENN) is often used to determine such thresholds. An important part of these models are the membrane channel dynamics describing the ionic transmembrane currents. This work shows how ELVs change significantly with different ion channel dynamics (up to a factor of 22). Furthermore, two more detailed double-cable models by Gaines et al. (MRG-Sensory and MRG-Motor) are also considered in this work. Thresholds calculated with the SENN model (with Frankenhaeuser-Huxley membrane channel dynamics) and the MRG models are compared for frequencies between 1 Hz and 100 kHz and temperatures between 22 {degrees}C and 37 {degrees}C. Results show that MRG thresholds are lower than SENN thresholds. In the context of occupational ELVs, using the double cable model would lead to approximately ten times lower limit values. Therefore, future exposure guidelines should take the influence of different electrostimulation models into account when deriving ELVs. HighlightsO_LIDifferent membrane channel dynamics change derived exposure limit values by more than one order of magnitude. C_LIO_LIDouble-cable models result in a reduction of derived exposure limit values by one order of magnitude. C_LIO_LILower temperatures reduce the action potential thresholds at frequencies below 300 Hz. C_LI

physiology↗